Fan Controller
A case of really bad design
|
|
This repair story is about
a ceiling fan that was being used for the very first time after
being installed.
It had been more convenient
to mount the power supply for the so-called 24Volt fan motor
in the loft above the bedroom ceiling. The reason for installing
the fan was the series of UK heat waves in Summer 2026. Of course
ceiling fans must predominantly be used when its hot weather
and hot weather in a modern loft means really high temperatures
in the loft space. Bearing all this in mind a fan controller
design engineer must understand all the parameters involved especially
temperature characteristics.
A picture from a sales brochure.
|
|
 |
 |
The fan stopped working
during the night and failed to respond to its remote control.
As I was visiting the next morning
I suggested I fix the problem and was presented with this plastic-cased
controller in a very sorry state.
You can see here that the fan
is Model FYD-3517 and refers to its Instruction manual. I haven't
found one yet.
The manufacturer appears to
be
Foshan Shunde Fengyun Electric
Appliance Co.,Ltd.
I've requested a copy of the
instruction manual.
Extracting the circuit board
wasn't difficult and I found a dead short across the three paralled
smoothing capacitors for providing 24 volts DC.
The worrying point is that the
mains fuse is still intact.
|
|
 |
I counted the components
wired to the short and found two DPAK chips, three capacitors
and three motor driver chips. The DPAK devices are marked MOT10200D and are dual Schottky diodes
making one or more shorts in ten possible devices.
Below is the circuit showing
the 24 volt PSU driven from the HF transformer (which I found
was running at about 320KHz). Rather than removing and testing
each component in turn I used my thermal camera. Connecting a
current limited low voltage with the same polarity as the capacitors
I cranked up the current and voltage.
One of the Schottky dual diode
chips won easily by getting much hotter than the remaineder of
the parts.
I removed the chip and found
one of its diodes was short-circuit and the other quite leaky
with the rest of the circuit normal (in fact I applied mains
power and measured 24 volts across the capacitors).
|
|
 |
|
If you examine the circuit
above you'll see there are four paralleled diodes. This is generally
a really bad idea because, although each diode is rated at up
to 5A, its actual forward current is influenced by the resistance
of the diode when conducting meaning that each diode will rectify
not a quarter of the load current, but a bit more or a bit less
than this depending on its forward resistance relative to the
others. At room temperature 20A capability seems OK to handle
a mere 2A, but raise the ambient temperature and look at the
diode junction temperature and the 10A capability of the MOT10200D
starts to drop off. A worrying feature now becomes apparent in
that any upward change in forward resistance due to rising temperature
may begin a current hogging process. Once one of the four diodes
sinking more current than its share its junction temperature
will keep on rising until you get thermal runaway. One diode
then sinks most of the current when its now too hot to handle
this amount and its semiconductor junction fails short circuit.
This is what happened because
the ambient temperature in the heat wave, in the loft, and under
lagging (meaning very little ventilation) placed the MOT10200D
outside its safe operating area. Basically at a junction temperature
of 175C the "safe operating area" dictates zero current
can be handled.
Below is the repaired controller
with its RF handset.
|
|
 |
|
What was the solution?
First of all I wanted to use a heatsink (none was originally
fitted). I considered using a TO220 device but then decided a
stud-mounted single diode was best. In my spares collection I
found a BYW30-300. This is a stud
mounted ultra fast rectifier (30nS) which can handle 20A at up
to 300VRMS. Pretty special... and dead easy to mount on a heatsink.
The repaired controller is not too easy to test as I don't have
the 3-phase DC fan but I connected three 330 ohm resistors across
the three output wires and using the remote control saw the voltages
crank up.
In the picture above the mains
wires are not UK standard, having USA colours of black-live and
white-neutral. Red and blue feed a lamp via a small relay and
white/pink/yellow feed the fan. The black wire is the antenna
for picking up the remote control signal in the 70cm band.
Finally.. rounding up. The controller
is potentially dangerous if operated in an environment having
little or no ventilation. Although the controller was inoperative
and with a badly melted and deformed casing the mains fuse was
intact. I've contacted the manufacturer to see if I can get a
user manual so I can see details of the installation.
|
|
|
|